The Panel
A 92 × 30 cm panel with eight wavelengths and a dimmer on each, set parallel to the skin over the table. Supplied to clinics only.
Clinical photobiomodulation · Brisbane
Red and near-infrared LED panels for acupuncture, remedial massage, physiotherapy and osteopathy rooms. One panel over the treatment table, a dose you can write in the notes, and a session that runs while you are with the next patient.
For clinic owners, practice managers and registered practitioners.
Where it fits
A panel needs two things your room may already have: bare skin over the area, and a few still minutes. Where both exist, the session fits inside the appointment and no visit gets longer.
Where it does not fit: five-minute appointments with the patient fully dressed. Light does not pass through clothing, and we would rather say so now.
A focal probe covers a few square centimetres at a time. An LED panel irradiates a whole muscle group or joint region in a single exposure.
Position, set the timer, stay within call. The session runs without handheld delivery, in the treatment room or in a spare one.
Irradiance measured at treatment distance, converted into exposure times by region. Level, time and distance go into the clinical notes.
Dosimetry
Fluence is irradiance multiplied by time. Every panel we supply comes with exposure times by region, calculated from the irradiance measured at your table.
J/cm² = mW/cm² × seconds ÷ 1000
Sources for each number are in the evidence section.
DOSE CALCULATOR · PRACTITIONER AREA
Choose the region and the stage of care. The calculator returns a timer setting in whole minutes at 40 cm, with the full dosimetry one tap away.
Because it gives dose guidance for a therapeutic good, it sits in the practitioner area. Access is sent with the clinical pack.
The mechanism
The leading hypothesis: red and near-infrared photons are absorbed by cytochrome c oxidase in the mitochondria and displace inhibitory nitric oxide, so electron transport resumes. It is well supported, and still a hypothesis.
Most of the energy is absorbed in the first millimetres of skin. Near-infrared scatters less and reaches further, at much lower intensity. Superficial muscle, tendon and joint are realistic targets. A deep hip joint is not.
The response is biphasic: too little does nothing, too much cancels the effect. One review found failed studies in muscle and nerve were more often overdosed than underdosed. Every protocol we write has a ceiling.
Huang et al., 2009 · Zein, Selting and Hamblin, 2018
Indicative, not to scale. In one study of an 850 nm laser, intensity fell by 66% across 0.78 mm of human skin. Depth also varies with tissue thickness, site and sex. This is why the panel combines both bands, and why surface dose is set higher than the dose intended at depth.
The devices
A 92 × 30 cm panel with eight wavelengths and a dimmer on each, set parallel to the skin over the table. Supplied to clinics only.
A mobile stand with powered height adjustment. It carries the clinic panel between rooms and sets it at working distance.
A compact panel for patients who continue at home. A standard course is two to three sessions a week, and most patients attend once. Supplied through your clinic, on your recommendation.
Every panel includes the dose protocol and onboarding for each clinician who will use it.
The evidence
Photobiomodulation evidence is protocol-specific. These are the sources behind our dose levels, with their limits stated.
Navarro-Ledesma S, et al. Whole-body photobiomodulation in fibromyalgia. Pain and Therapy. 2022.
Triple-blinded trial of whole-body red and near-infrared LED: 25.2 J/cm² over 20 minutes, 12 sessions in 4 weeks, with pain reduced against placebo. A different device and condition, sponsored by a manufacturer. It supports our dose range, not a claim for any condition.
No agreed parameters. Some groups advise under 100 mW/cm² and 4 to 10 J/cm² at the target tissue; others up to 50 J/cm² at the surface. Basis for our 45 J/cm² ceiling and for keeping irradiance under 100.
World Association for Laser Therapy. Recommended treatment doses, 780 to 860 nm. 2010.
Laser doses in joules per point, which cannot be converted to a panel fluence. It supports the session frequency and the 30% reduction once pain is settling.
Heiskanen V, Hamblin MR. Photobiomodulation: lasers vs. light emitting diodes? Photochem Photobiol Sci. 2018;17:1003–1017.
Perspective review of the LED literature. Treats non-coherent LED sources as an established PBM modality. Direct head-to-head trials remain few.
Chow R, Liebert A, Tilley S, et al. Guidelines versus evidence: the Australian guideline for low-level laser therapy in knee osteoarthritis. Lasers Med Sci. 2021;36(2).
The 2018 RACGP guideline was conditionally against low-level laser for knee osteoarthritis. This review argues the evidence supports revision. The question is open.
We found no published trial of a panel at 40 cm over a treatment table. That configuration is untested in the literature we reviewed, and we say so in the clinical pack.
The process
Specification sheet, dose protocol, regulatory file and reference list, sent before any call.
We bring the unit to your clinic, measure irradiance at your table height and walk your team through the protocol.
Placement, screening, eye-safety procedure and dose tables covered with every clinician who will use it.
Sessions delivered against capacity, reviewed together once the panel is in routine use.
The clinical pack
Tell us about your practice and we will send the specification, the dose protocol and the reference list. No sales sequence.
Or write to tomas@tobomolabs.com